#MegaCli -PDList -aALL Adapter #0 Enclosure Device ID: 252 Slot Number: 0 Drive's postion: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: N/A Device Id: 9 WWN: 500000******** Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 136.731 GB [0x11176d60 Sectors] Non Coerced Size: 136.231 GB [0x11076d60 Sectors] Coerced Size: 135.972 GB [0x10ff2000 Sectors] Firmware state: Online, Spun Up Device Firmware Level: SC17 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x500000e117fae4f2 SAS Address(1): 0x0 Connected Port Number: 1(path0) Inquiry Data: IBM-ESXSMBE2147RC SC17D300DKF*****C17SC17 IBM FRU/CRU: 42D0668 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :37C (98.60 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 252 Slot Number: 1 Drive's postion: DiskGroup: 0, Span: 0, Arm: 1 Enclosure position: N/A Device Id: 8 WWN: 500000E****E87F1 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 136.731 GB [0x11176d60 Sectors] Non Coerced Size: 136.231 GB [0x11076d60 Sectors] Coerced Size: 135.972 GB [0x10ff2000 Sectors] Firmware state: Online, Spun Up Device Firmware Level: SC17 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x500000e117fe87f2 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: IBM-ESXSMBE2147RC SC17D300DNJVSC17SC17SC17 IBM FRU/CRU: 42D0668 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :36C (96.80 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Exit Code: 0x00
2.すべてのコントローラーのプロパティ
MegaCli -AdpAllInfo -aALL
Adapter #0
==============================================================================
Versions
================
Product Name : ServeRAID M5015 SAS/SATA Controller
Serial No : SV120*****
FW Package Build: 12.12.0-0056
Mfg. Data
================
Mfg. Date : 05/12/11
Rework Date : 00/00/00
Revision No : 56A
Battery FRU : N/A
Image Versions in Flash:
================
FW Version : 2.120.113-1307
BIOS Version : 3.22.00_4.11.05.00_0x0501A000
Preboot CLI Version: 04.04-017:#%00008
WebBIOS Version : 6.0-40-e_35-Rel
NVDATA Version : 2.09.03-0015
Boot Block Version : 2.02.00.00-0000
BOOT Version : 09.250.01.219
Pending Images in Flash
================
None
PCI Info
================
Controller Id : 0000
Vendor Id : 1000
Device Id : 0079
SubVendorId : 1014
SubDeviceId : 03b2
Host Interface : PCIE
ChipRevision : B4
Number of Frontend Port: 0
Device Interface : PCIE
Number of Backend Port: 8
Port : Address
0 500000e117fe****
1 500000e117fa****
2 0000000000000000
3 0000000000000000
4 0000000000000000
5 0000000000000000
6 0000000000000000
7 0000000000000000
HW Configuration
================
SAS Address : 500605b0037*****
BBU : Present
Alarm : Present
NVRAM : Present
Serial Debugger : Present
Memory : Present
Flash : Present
Memory Size : 512MB
TPM : Absent
On board Expander: Absent
Upgrade Key : Present
Temperature sensor for ROC : Absent
Temperature sensor for controller : Absent
Settings
================
Current Time : 2:33:19 6/12, 2013
Predictive Fail Poll Interval : 300sec
Interrupt Throttle Active Count : 16
Interrupt Throttle Completion : 50us
Rebuild Rate : 30%
PR Rate : 30%
BGI Rate : 30%
Check Consistency Rate : 30%
Reconstruction Rate : 30%
Cache Flush Interval : 4s
Max Drives to Spinup at One Time : 4
Delay Among Spinup Groups : 2s
Physical Drive Coercion Mode : 1GB
Cluster Mode : Disabled
Alarm : Disabled
Auto Rebuild : Enabled
Battery Warning : Enabled
Ecc Bucket Size : 15
Ecc Bucket Leak Rate : 1440 Minutes
Restore HotSpare on Insertion : Disabled
Expose Enclosure Devices : Enabled
Maintain PD Fail History : Enabled
Host Request Reordering : Enabled
Auto Detect BackPlane Enabled : SGPIO/i2c SEP
Load Balance Mode : Auto
Use FDE Only : Yes
Security Key Assigned : No
Security Key Failed : No
Security Key Not Backedup : No
Default LD PowerSave Policy : Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 120
Auto Enhanced Import : No
Any Offline VD Cache Preserved : No
Allow Boot with Preserved Cache : No
Disable Online Controller Reset : No
PFK in NVRAM : No
Use disk activity for locate : No
POST delay : 90 seconds
Capabilities
================
RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Supported Drives : SAS, SATA
Allowed Mixing:
Mix in Enclosure Allowed
Status
================
ECC Bucket Count : 0
Limitations
================
Max Arms Per VD : 32
Max Spans Per VD : 8
Max Arrays : 128
Max Number of VDs : 64
Max Parallel Commands : 1008
Max SGE Count : 80
Max Data Transfer Size : 8192 sectors
Max Strips PerIO : 42
Max LD per array : 16
Min Strip Size : 8 KB
Max Strip Size : 1.0 MB
Max Configurable CacheCade Size: 0 GB
Current Size of CacheCade : 0 GB
Current Size of FW Cache : 397 MB
Device Present
================
Virtual Drives : 1
Degraded : 0
Offline : 0
Physical Devices : 3
Disks : 2
Critical Disks : 0
Failed Disks : 0
Supported Adapter Operations
================
Rebuild Rate : Yes
CC Rate : Yes
BGI Rate : Yes
Reconstruct Rate : Yes
Patrol Read Rate : Yes
Alarm Control : Yes
Cluster Support : No
BBU : Yes
Spanning : Yes
Dedicated Hot Spare : Yes
Revertible Hot Spares : Yes
Foreign Config Import : Yes
Self Diagnostic : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares : Yes
Deny SCSI Passthrough : No
Deny SMP Passthrough : No
Deny STP Passthrough : No
Support Security : Yes
Snapshot Enabled : No
Support the OCE without adding drives : Yes
Support PFK : No
Support PI : No
Support Boot Time PFK Change : No
Disable Online PFK Change : No
Support Shield State : No
Block SSD Write Disk Cache Change: No
Supported VD Operations
================
Read Policy : Yes
Write Policy : Yes
IO Policy : Yes
Access Policy : Yes
Disk Cache Policy : Yes
Reconstruction : Yes
Deny Locate : No
Deny CC : No
Allow Ctrl Encryption: No
Enable LDBBM : No
Support Breakmirror : No
Power Savings : No
Supported PD Operations
================
Force Online : Yes
Force Offline : Yes
Force Rebuild : Yes
Deny Force Failed : No
Deny Force Good/Bad : No
Deny Missing Replace : No
Deny Clear : No
Deny Locate : No
Support Temperature : Yes
Disable Copyback : No <--Copyback有効
Enable JBOD : No
Enable Copyback on SMART : No
Enable Copyback to SSD on SMART Error : Yes
Enable SSD Patrol Read : No
PR Correct Unconfigured Areas : Yes
Enable Spin Down of UnConfigured Drives : Yes
Disable Spin Down of hot spares : Yes
Spin Down time : 30
T10 Power State : No
Error Counters
================
Memory Correctable Errors : 0
Memory Uncorrectable Errors : 0
Cluster Information
================
Cluster Permitted : No
Cluster Active : No
Default Settings
================
Phy Polarity : 0
Phy PolaritySplit : 0
Background Rate : 30
Strip Size : 128kB
Flush Time : 4 seconds
Write Policy : WB <--書き込みキャッシュ有効
Read Policy : None
Cache When BBU Bad : Disabled
Cached IO : No
SMART Mode : Mode 6
Alarm Disable : No
Coercion Mode : 1GB
ZCR Config : Unknown
Dirty LED Shows Drive Activity : No
BIOS Continue on Error : No
Spin Down Mode : None
Allowed Device Type : SAS/SATA Mix
Allow Mix in Enclosure : Yes
Allow HDD SAS/SATA Mix in VD : No
Allow SSD SAS/SATA Mix in VD : No
Allow HDD/SSD Mix in VD : No
Allow SATA in Cluster : No
Max Chained Enclosures : 16
Disable Ctrl-R : Yes
Enable Web BIOS : Yes
Direct PD Mapping : No
BIOS Enumerate VDs : Yes
Restore Hot Spare on Insertion : No
Expose Enclosure Devices : Yes
Maintain PD Fail History : Yes
Disable Puncturing : Yes
Zero Based Enclosure Enumeration : No
PreBoot CLI Enabled : Yes
LED Show Drive Activity : No
Cluster Disable : Yes
SAS Disable : No
Auto Detect BackPlane Enable : SGPIO/i2c SEP
Use FDE Only : Yes
Enable Led Header : No
Delay during POST : 4
EnableCrashDump : No
Disable Online Controller Reset : No
EnableLDBBM : No
Un-Certified Hard Disk Drives : Allow
Treat Single span R1E as R10 : No
Max LD per array : 16
Power Saving option : Don't spin down Hot spares
Don't Auto spin down Configured Drives
Max power savings option is not allowed for LDs. Only T10 power conditions are to be used.
Default spin down time in minutes: 30
Enable JBOD : No
TTY Log In Flash : No
Auto Enhanced Import : No
BreakMirror RAID Support : No
Disable Join Mirror : No
Enable Shield State : No
Time taken to detect CME : 60s
Exit Code: 0x00
3.すべてのコントローラーのバッテリーの状態を表示
#MegaCli -AdpBbuCmd -aALL BBU status for Adapter: 0 BatteryType: iBBU08 Voltage: 4034 mV Current: 0 mA Temperature: 35 C Battery State : Non Operational BBU Firmware Status: Charging Status : None Voltage : OK Temperature : OK Learn Cycle Requested : Yes Learn Cycle Active : No Learn Cycle Status : OK Learn Cycle Timeout : No I2c Errors Detected : No Battery Pack Missing : No Battery Replacement required : No <--YESだとバッテリー交換時期 Remaining Capacity Low : No Periodic Learn Required : No Transparent Learn : No No space to cache offload : No Pack is about to fail & should be replaced : No Cache Offload premium feature required : No Module microcode update required : No BBU GasGauge Status: 0x0280 Relative State of Charge: 100 % Charger System State: 1 Charger System Ctrl: 0 Charging current: 0 mA Absolute state of charge: 0 % Max Error: 0 % Battery backup charge time : 48 hours + BBU Capacity Info for Adapter: 0 Relative State of Charge: 100 % <--フル充電時の容量に対する現在の充電の割合 Absolute State of charge: 86 % <--仕様上のバッテリキャパシティに対する現在の充電の割合 Remaining Capacity: 1317 mAh Full Charge Capacity: 1317 mAh Run time to empty: Battery is not being discharged. Average time to empty: 2 Hour, 38 Min. Estimated Time to full recharge: Battery is not being charged. Cycle Count: 16 BBU Design Info for Adapter: 0 Date of Manufacture: 05/26, 2011 Design Capacity: 1530 mAh Design Voltage: 4100 mV Specification Info: 0 Serial Number: 4665 Pack Stat Configuration: 0x0000 Manufacture Name: LS36681 Device Name: bq27541 Device Chemistry: LPMR Battery FRU: N/A Transparent Learn = 0 App Data = 0 BBU Properties for Adapter: 0 Auto Learn Period: 30 Days Next Learn time: Jun 19 2013 15:20:02 Learn Delay Interval:0 Hours Auto-Learn Mode: Enabled BBU Mode = 5 Exit Code: 0x00
4.既存構成の表示
MegaCli -CfgDsply -aALL ============================================================================== Adapter: 0 Product Name: ServeRAID M5015 SAS/SATA Controller Memory: 512MB BBU: Present Serial No: SV12013*** ============================================================================== Number of DISK GROUPS: 1 DISK GROUP: 0 Number of Spans: 1 SPAN: 0 Span Reference: 0x00 Number of PDs: 2 Number of VDs: 1 Number of dedicated Hotspares: 0 Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 60.0 GB Mirror Data : 60.0 GB State : Optimal <--現在のアレイのステータス Strip Size : 128 KB Number Of Drives : 2 Span Depth : 1 Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disabled Encryption Type : None Is VD Cached: No Physical Disk Information: Physical Disk: 0 Enclosure Device ID: 252 <--エンクロージャーID Slot Number: 0 <--ID,0のハードディスク Drive's postion: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: N/A Device Id: 9 WWN: 500000E117****** Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 136.731 GB [0x11176d60 Sectors] Non Coerced Size: 136.231 GB [0x11076d60 Sectors] Coerced Size: 135.972 GB [0x10ff2000 Sectors] Firmware state: Online, Spun Up Device Firmware Level: SC17 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x500000e117f***** SAS Address(1): 0x0 Connected Port Number: 1(path0) Inquiry Data: IBM-ESXSMBE2147RC SC17D300DKFNSC17SC17SC17 IBM FRU/CRU: 42D0668 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :37C (98.60 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Physical Disk: 1 Enclosure Device ID: 252 Slot Number: 1 <--スロット2のハードディスク Drive's postion: DiskGroup: 0, Span: 0, Arm: 1 Enclosure position: N/A Device Id: 8 WWN: 500000E117F***** Sequence Number: 2 Media Error Count: 0 <--ディスク媒体系のエラーカウント Other Error Count: 0 <--I/F系のエラーカウント Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 136.731 GB [0x11176d60 Sectors] Non Coerced Size: 136.231 GB [0x11076d60 Sectors] Coerced Size: 135.972 GB [0x10ff2000 Sectors] Firmware state: Online, Spun Up Device Firmware Level: SC17 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x500000e117fe87f2 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: IBM-ESXSMBE2147RC SC17D300DNJVSC17SC******* IBM FRU/CRU: 42D0668 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :36C (96.80 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Exit Code: 0x00
5.格納装置情報の表示
MegaCli -EncInfo -aALL
Number of enclosures on adapter 0 -- 1
Enclosure 0:
Device ID : 252
Number of Slots : 8
Number of Power Supplies : 0
Number of Fans : 0
Number of Temperature Sensors : 0
Number of Alarms : 0
Number of SIM Modules : 1
Number of Physical Drives : 2 <--このエンクロージャーに接続されている物理HDD
Status : Normal
Position : 1
Connector Name : Unavailable
Enclosure type : SGPIO
FRU Part Number : N/A
Enclosure Serial Number : N/A
ESM Serial Number : N/A
Enclosure Zoning Mode : N/A
Partner Device Id : Unavailable
Inquiry data :
Vendor Identification : LSI
Product Identification : SGPIO
Product Revision Level : N/A
Vendor Specific :
Exit Code: 0x00
6.端末ログの表示
MegaCli -FwTermLog -Dsply -aALL <--イベントログの出力 T570: RMW: NVRAM structure valid - checking for active RMWs 06/11/13 22:43:58: EVT#14853-06/11/13 22:43:58: 44=Time established as 06/11/13 22:43:58; (570 seconds since power on) 06/11/13 22:44:09: Battery Reached EOL 06/11/13 22:44:09: EVT#14854-06/11/13 22:44:09: 253=Battery requires reconditioning; please initiate a LEARN cycle 06/11/13 22:44:09: Battery Yearly Deep Discharge Relearn Pending. Please Initiate a manual Relearn 06/11/13 22:45:59: EVT#14855-06/11/13 22:45:59: 44=Time established as 06/11/13 22:45:59; (691 seconds since power on) 06/11/13 22:51:50: Driver Version: 00.00.05.38-rh1 06/11/13 22:51:50: MSI-X Enabled: MSIX offset = 00002000 06/11/13 22:51:50: MSIX[0]: 00000000:fee00000 - 4082 06/11/13 22:51:50: MSIX[1]: 00000000:00000000 - 0 06/11/13 22:51:50: MSIX[2]: 00000000:00000000 - 0 06/11/13 22:51:50: MSIX[3]: 00000000:00000000 - 0 06/11/13 22:51:50: findMsiState: Setting MSI Mode to 2 (0=Legacy, 1=MSI, 2=MSI-X) 06/11/13 22:51:50: EVT#14856-06/11/13 22:51:50: 389=Host driver is loaded and operational 06/11/13 22:51:50: MfiCmdInitQueue[0]: FW now OPERATIONAL 06/11/13 22:51:50: q.flags.mfaIs64Bits=0, q.flags.contextIs64Bits=0 06/11/13 22:51:50: q.responseQueueEntries=3f0, responseQueueStatr=7f63e000 06/11/13 22:51:50: q.producerIndexPtr=37f4e000, q.consumerIndexPtr=37f4f000 06/11/13 22:51:50: producerIndex=0 06/11/13 23:09:27: shutdownBlockDone: wait for all IO to complete 06/11/13 23:09:27: shutdownBlockDone: IO complete; wait for host command 06/11/13 23:09:27: EVT#14857-06/11/13 23:09:27: 42=Shutdown command received from host 06/11/13 23:09:27: pciErrorInt: iopIntStatus 400 06/11/13 23:09:27: PCI-E link went down, resetting chip... T88: ddfInitStatus: 0 T88: configRaid: adding to raid config T88: configRaidAddSpan: adding ld=0 span=0 T88: ddfInitStatus after CheckForOfflinePRL11VDs : 0 T88: rollBackActiveTargetIds=0 ,missingRepTargetIds=0 T126: bumpCharge_iBBU08 : Expander_GPIO Data being Written = 0xff T126: EVT#14873-T126: 149=Battery temperature is normal T191: EVT#14874-T191: 147=Battery started charging T191: InhibitCharging : i2cExpander_GPIOstatus = 0xfe T256: EVT#14875-T256: 242=Battery charge complete T568: init_cache: recoverCache = 0 pinned_cache_present = 0 T568: Memory End 9ffffff0 T568: Total memory available for disk cache: 19019478 T568: Total Number of Cache Lines 3179 T568: SS 256: ss=8 mrs=2 lc=3179 ldc=1 ps=3 cm=ff ba=0 LDs: 0 T568: Cache initialization complete...Config info T568: ARs configured: 1 T568: Ar 0: size=10ff2000, activeLd=1, numPd=2, seq=0, powerSave=0 powerSaveInProgress=0 PDs: 09(fc/0) 08(fc/1) T568: LD 0: L=1 SS=256 Size=7800000 NL=3179 Status=3 DT=1398 BT=2215, Encr=0, prop=[ID=00,dcp=01,ccp=01,ap=0,dc=2,dbgi=0,S=0|0,dps=00,cps=fe] T568: span 0: sBlk=00000000, nBlk=07800000, ar=0 T568: max-flush (Ar 0): 0x30 T568: setup_cache_headers: ***** totalDirtyLines: 0 recoverCache: 0 T568: pdFailHistInit: count=0 T568: pdFailHistInit: count=0 T568: Initializing write journal entries T568: NOT Flushing Cache T568: RMW: NVRAM structure valid - checking for active RMWs 06/11/13 23:19:01: EVT#14876-06/11/13 23:19:01: 44=Time established as 06/11/13 23:19:01; (569 seconds since power on) 06/11/13 23:19:13: Battery Reached EOL 06/11/13 23:19:13: EVT#14877-06/11/13 23:19:13: 253=Battery requires reconditioning; please initiate a LEARN cycle 06/11/13 23:19:13: Battery Yearly Deep Discharge Relearn Pending. Please Initiate a manual Relearn 06/11/13 23:21:01: EVT#14878-06/11/13 23:21:01: 44=Time established as 06/11/13 23:21:01; (690 seconds since power on) 06/11/13 23:21:01: DDF updates for pr properties disabled 06/11/13 23:21:01: DDF updates for cc properties disabled 06/11/13 23:22:50: Driver Version: 00.00.05.38-rh1 06/11/13 23:22:50: MSI-X Enabled: MSIX offset = 00002000 06/11/13 23:22:50: MSIX[0]: 00000000:fee00000 - 4082 06/11/13 23:22:50: MSIX[1]: 00000000:00000000 - 0 06/11/13 23:22:50: MSIX[2]: 00000000:00000000 - 0 06/11/13 23:22:50: MSIX[3]: 00000000:00000000 - 0 06/11/13 23:22:50: findMsiState: Setting MSI Mode to 2 (0=Legacy, 1=MSI, 2=MSI-X) 06/11/13 23:22:50: EVT#14879-06/11/13 23:22:50: 389=Host driver is loaded and operational 06/11/13 23:22:50: MfiCmdInitQueue[0]: FW now OPERATIONAL 06/11/13 23:22:50: q.flags.mfaIs64Bits=0, q.flags.contextIs64Bits=0 06/11/13 23:22:50: q.responseQueueEntries=3f0, responseQueueStatr=7f65d000 06/11/13 23:22:50: q.producerIndexPtr=7d6ad000, q.consumerIndexPtr=7d6ae000 06/11/13 23:22:50: producerIndex=0 Exit Code: 0x00
7.論理ディスクの構成表示
MegaCli -LdPdInfo -aALL
Adapter #0
Number of Virtual Disks: 1
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 60.0 GB
Mirror Data : 60.0 GB
State : Optimal
Strip Size : 128 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disabled
Encryption Type : None
Is VD Cached: No
Number of Spans: 1
Span: 0 - Number of PDs: 2
PD: 0 Information
Enclosure Device ID: 252
Slot Number: 0
Drive's postion: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: N/A
Device Id: 9
WWN: 500000E117FAE4F1
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 136.731 GB [0x11176d60 Sectors]
Non Coerced Size: 136.231 GB [0x11076d60 Sectors]
Coerced Size: 135.972 GB [0x10ff2000 Sectors]
Firmware state: Online, Spun Up
Device Firmware Level: SC17
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x500000e117*****
SAS Address(1): 0x0
Connected Port Number: 1(path0)
Inquiry Data: IBM-ESXSMBE2147RC SC17D300DKFNSC17SC1*****
IBM FRU/CRU: 42D0668
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :37C (98.60 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
PD: 1 Information
Enclosure Device ID: 252
Slot Number: 1
Drive's postion: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: N/A
Device Id: 8
WWN: 500000E11******
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 136.731 GB [0x11176d60 Sectors]
Non Coerced Size: 136.231 GB [0x11076d60 Sectors]
Coerced Size: 135.972 GB [0x10ff2000 Sectors]
Firmware state: Online, Spun Up
Device Firmware Level: SC17
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x500000e117*******
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: IBM-ESXSMBE2147RC SC17D300DNJVSC17S*******
IBM FRU/CRU: 42D0668
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :36C (96.80 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00
Megacliのベース的なコマンドはこんな感じ♪